top of page

Lubricant Equivalents: Understanding Match Percentages

Nov 17
4 min read

Lube Store’s possible-equivalent cards help you shortlist products across Mobil, Shell, TotalEnergies and Caltex. Each card compares a particular product and grade using the evidence recorded in our technical review. This guide explains how to read the result, identify what remains uncertain and request a decision for your equipment.

Start with the exact product and the job it performs

Record the full product name, viscosity or grease grade, equipment model and lubrication point. A family name can include several formulations. Changing the selected grade on a Lube Store product page changes the comparison; an assessment for one variant should not be carried over to another.

A possible equivalent is a candidate for assessment in a stated duty. It is not an instruction to replace the oil already in service. Equipment requirements and the current regional product documents determine whether a shortlisted product can be accepted.

The five checks in every comparison

1. Viscosity grade

Check the required ISO VG or SAE grade. Review viscosity at the relevant temperatures and cold-start requirements where applicable. For grease, assess NLGI consistency alongside the base oil viscosity.

2. Base oil type

Identify the base-fluid chemistry from reliable product information. The description “synthetic” alone does not establish compatibility or justify carrying over the existing service interval.

3. Performance specifications

Compare the exact standard and performance category required for the duty. A shared grade does not establish that two products meet the same hydraulic, gear, engine or transmission specification.

4. OEM approvals

Check the equipment manufacturer’s requirement against the precise product approval. Keep formal approvals distinct from manufacturer statements that a product meets or is recommended for a specification.

5. Application-specific properties

Confirm the properties that matter at the lubrication point: operating temperature, load, water exposure, seals, filtration or grease thickener compatibility. Specialist duties may impose additional requirements.

How the matching percentage is calculated

Lube Store uses an equal-weight screening method. Each of the five criteria can contribute up to 20 points, giving a fixed total of 100. The score is calculated from the recorded assessment of that product pair; it is not a percentage of chemical ingredients or a laboratory prediction of service life.

  • Match — 20 points: the reviewed evidence supports agreement for that criterion within the recorded scope.

  • Partial — 10 points: there is documented overlap, but a difference or limitation remains.

  • Unknown — 0 points: there is insufficient evidence to assess the criterion. This is an information gap, not a finding that the products are incompatible.

  • Conflict — 0 points: the evidence identifies a mismatch. A disqualifying conflict excludes the candidate, regardless of points earned elsewhere.

The denominator always stays at 100. Unknown criteria are never removed from the calculation to make the percentage look higher. A numerical ring is displayed only when both products have supporting references and at least two criteria have been assessed. Otherwise, the ring shows a dash and “Review pending”.

Read evidence coverage alongside the score

Evidence coverage measures how much of the five-criterion review has an assessed outcome. Match, Partial and Conflict each count as assessed; Unknown does not. Each assessed criterion contributes 20 percentage points of coverage.

Example: two Match outcomes and three Unknown outcomes give a 40% documented match and 40% evidence coverage. That means two criteria have supporting agreement and three remain unresolved. It does not mean the oil is “40% suitable” for your machine.

Example: two Match outcomes, one Partial and two Unknown outcomes give a 50% documented match and 60% evidence coverage. More information has been reviewed than has been confirmed as matching.

Why a high score still needs a technical decision

The five equal weights make the display consistent; they do not make every requirement equally important in service. One mandatory equipment approval or an unsuitable fluid chemistry can outweigh several similarities. Even a 100% recorded score would describe the reviewed scope, not universal interchangeability.

An OEM-approval check may remain Unknown even when the two datasheets list overlapping approvals, because the equipment model and its mandatory requirement have not been supplied. An application check may likewise remain open until the operating conditions are known. The required-check notes show what is needed to close these gaps.

Replacement and mixing are separate decisions

A product that is acceptable after a planned changeover may still be unsuitable for topping up the existing charge. Compatibility depends on the actual fluids, additives, materials and condition of the system. Obtain product-specific changeover guidance, including whether draining, cleaning or flushing is required, before mixing or switching. Do not assume a mixed charge retains either product’s original approvals.

Use the product cards to request a review

  • Select the exact catalogue grade and open “Five criteria & required checks” on the candidate card.

  • Read the evidence and unresolved checks, then open the relevant technical references. Confirm that each document covers the correct product, grade and market.

  • Provide the equipment make and model, lubrication point, current lubricant, operating conditions and any required approval.

  • State whether you intend a full changeover or a top-up, and include the current oil’s condition or recent analysis if available.

  • Choose “Request an alternative check” on the product page, or use “Request A Quote” in the site menu to describe your requirement.

Some brands or grades will have no supported candidate in the reviewed information. That is shown explicitly rather than filling the space with an unverified substitute. New datasheets or equipment details may change an assessment; always read the review date and the current required checks.

Lube Store comparison methodology • Updated 17 November 2026

 
 
 