A work order that says “lubricate the conveyor” leaves three questions unanswered. Does the gearbox need oil? Can the motor bearings be regreased? How will oil reach the joints of the drive chain? A single machine can have a different answer at every lubrication point. Here’s how to turn that instruction into a purchase specification and a maintenance task someone can carry out.


Start with the lubrication point


Take the make, model and serial number from the nameplate, then find the lubrication entry for that component in the equipment manufacturer’s manual. For a gearbox, record the oil type, viscosity grade and any required approval. For a bearing, check whether it is sealed for life or designed for relubrication. Only the latter belongs on a routine regreasing schedule.


Next, record the conditions that could change the choice. A conveyor gearbox that starts under load after a long stop faces different demands from one that runs steadily. At a UAE quarry, note the cold-start and normal operating temperatures, dust around the fill point and any washdown water reaching the seals. If the measured conditions fall outside the manual’s guidance, take those readings to the manufacturer before changing the grade.


Read the number on the label


For industrial oils, ISO VG describes kinematic viscosity at 40 °C. It tells you how readily the oil flows at that reference temperature. To decide whether it belongs in a particular component, you also need the performance specification.


Consider two products a buyer might encounter. Mobil DTE 25 Ultra is an ISO VG 46 anti-wear hydraulic oil. Mobil DTE 746 is also ISO VG 46 and is formulated for turbine service. An order for “46 oil” could bring either one to the stores counter. Include the application and the required specification on the order.



ISO VG 32, 46 and 68 indicate increasing oil viscosity at 40 °C. NLGI 1, 2 and 3 indicate increasingly firm grease at 25 °C. Check grease base oil viscosity separately.

For grease, the NLGI number describes consistency. Two NLGI 2 greases can contain base oils of different viscosities and use different thickeners. For a bearing, check the base oil viscosity against its speed, load and operating temperature. Then check thickener type, water resistance where relevant and suitability for the delivery system.


A tapered roller bearing with amber grease visible between the steel rollers and its outer race behind it.
A bearing grease specification needs both the consistency grade and the base oil viscosity.

Match the application method to the machine


The equipment design determines how lubricant reaches the contact. Identify the installed arrangement before deciding what to put on the maintenance route.


Four delivery methods and their checks. For splash oil check sump level. For circulating oil check flow and filters. For grease feed verify dose and interval. For chain oil check delivery at the pin-and-bush joint.

Splash or bath lubrication. In a splash-lubricated gearbox, a gear dips into the sump and carries oil to the mesh. On a bath-lubricated unit, components may sit deeper in oil. Check the indicated level in the mounting position and machine state specified in the manual. A nominal capacity in litres is only a starting point when the manufacturer specifies a level mark.


Circulating oil. A pump carries oil to bearings or gears and the oil returns to a reservoir. The circuit may include a filter and cooler. A full reservoir tells you how much oil is available. The flow indicator and filter condition tell you more about whether it is getting where it needs to go.


Manual or automatic greasing. For a regreasable bearing, put the prescribed grams and interval on the job card. If you use a hand gun, verify its output per stroke with a scale or grease meter. On an automatic system, check the setting, the supply and delivery at the intended outlet. Excess grease can churn and raise bearing temperature.


Drip or brush oiling. On a conventional roller chain, oil needs to penetrate the gap between the link plates to reach the pin and bush. An oily roller surface alone tells you little about that joint. Use the chain maker’s delivery method for the drive speed. Isolate the drive before hand application and follow the site’s guarding and lockout procedure.


Make the changeover a separate decision


A cross-reference can identify a possible replacement. Before a brand switch, verify the specification and any required approval against the current product data sheet. Then confirm with the supplier or equipment manufacturer how to change over from the lubricant already in the machine. Even two greases with the same NLGI grade and thickener family can be incompatible. If the existing fill is unknown, identify it or agree a changeover procedure before topping up.


What to put on the work order


Give the technician the asset ID and exact point, approved product, quantity or level mark, application method, interval and check after service. For the example conveyor, that means separate entries for the reducer, each regreasable bearing and the chain. Label transfer containers and grease guns with the product they carry, keep fittings clean and record the quantity actually used. An unexplained increase in top-ups is a reason to look for a leak.


Ask Lube Store to review your application


Send our UAE team the equipment make and model, the lubrication page from the manual, the current product and the operating temperature. Tell us whether you need a first fill, a top-up or a change of brand. Those details let us review the specification and flag compatibility questions before you order.